Structural fill South Carolina — lab tested by Ground Tech and Proctor tested, available from Rebkee's dedicated borrow pit in Chester, SC. Strategically located approximately 45 miles south of Charlotte, NC and 75 miles east of Greenville, SC, this material is ideally positioned to serve two of the Southeast's fastest growing construction markets. This orange/brown sandy fill with silt and mica is ideal for structural fill applications, building pad construction, roadway projects, and site grading requiring verified, compaction tested fill material.
Quick Specs
| Detail | Information |
|---|---|
| Material | Structural Fill — Orange/Brown Sandy Fill |
| Visual Classification | Orange/brown sand, silt, mica |
| USCS Classification | Available on request |
| Composition | Sand ~90.3%, Fines ~7.3%, Gravel ~0.4% |
| Max Dry Density | 93.2 PCF |
| Optimum Moisture | 25.1% |
| Quantity Available | 2,000,000 CY |
| Certification | Lab tested by Ground Tech — Standard Proctor and Sieve Analysis (ASTM D698, AASHTO M145) |
| Location | Chester, SC 29374 (Chester County) |
| Loading | On-site excavator loading available |
| Delivery | Available — inquire for quote |
| Best For | Structural fill, building pads, roadways, backfill, site grading |
| Price | Inquire for pricing |
What is Structural Fill in South Carolina?
Structural fill South Carolina is a compaction tested fill material used to create a strong, stable base for construction projects. Unlike general purpose fill dirt, structural fill is Proctor tested to verify its maximum dry density and optimum moisture content — ensuring predictable, reliable compaction performance on every project. The material at this Chester, SC location is an orange/brown sandy fill with silt and mica, tested by Ground Tech in accordance with ASTM D698 Standard Proctor methods. Testing confirms a maximum dry density of 93.2 PCF at 25.1% optimum moisture. Sieve analysis confirms 90.3% sand content with minimal fines — making it suitable for a wide range of structural applications. For projects requiring additional documentation, full Ground Tech lab reports are available on request. Additional materials available from this location include engineered fill dirt and white sand fill. Looking for other fill dirt options across the Carolinas? Browse all fill dirt listings on BorrowPit.com.
Why This Listing Stands Out
- Lab tested by Ground Tech — Standard Proctor testing confirms max dry density of 93.2 PCF at 25.1% optimum moisture. Sieve analysis completed in accordance with AASHTO M145. Full documentation available on request
- High sand content — 90.3% sand with only 7.3% fines provides good drainage and consistent compaction performance
- Dedicated borrow pit — consistent, quality structural fill available from an active Chester SC excavation
- Strategically located — approximately 45 miles south of Charlotte, NC and 75 miles east of Greenville, SC
- Fast loading available — on-site CAT excavator ready to load all truck types
- Delivery available — inquire for quote based on quantity and location
Best Uses
- Structural fill for roadways and highway projects
- Building pad construction for commercial and industrial facilities
- Site grading and elevation raising
- Backfill for foundations, utilities, and retaining walls
- Embankment construction
- Large scale infrastructure and civil projects requiring Proctor tested fill
- Any project requiring compaction tested structural fill material
Service Area
Located in Chester, SC — approximately 45 miles south of Charlotte, NC and 75 miles east of Greenville, SC — this material serves Chester County and the greater Charlotte and Greenville metropolitan areas. With two of the Southeast's fastest growing construction markets within trucking distance, this listing is ideally positioned to supply major infrastructure, commercial, and industrial projects across the Carolinas.
Pickup available Monday through Thursday 9AM to 4PM, Friday 9AM to 1PM, and Saturday through Sunday by appointment. Delivery available — inquire for quote.
For roadway and infrastructure projects reference the South Carolina Department of Transportation. For projects in North Carolina reference the NCDOT Standard Specifications for Roads and Structures.
Frequently Asked Questions
Is this fill dirt lab tested? Yes. Material has been tested by Ground Tech in accordance with ASTM D698 Standard Proctor methods. Maximum dry density is 93.2 PCF at 25.1% optimum moisture. Sieve analysis confirms 90.3% sand, 7.3% fines, and 0.4% gravel. Full lab reports available on request.
How much is available? Over 2,000,000 CY
Is delivery available? Delivery options are available — contact for details and pricing based on quantity and location.
What are the hours? Monday through Thursday 9AM to 4PM, Friday 9AM to 1PM, Saturday and Sunday by appointment.
What is the price? Inquire for pricing — contact for a quote based on quantity and needs.
Where are you located? 1047 Pinckney Road, Chester, SC 29374. Located near SC Highway 9, approximately 45 miles south of Charlotte, NC and 75 miles east of Greenville, SC.